PROCEDURE
INSTALL MAIN BODY ECU
Note
Make sure that there is no foreign matter in the engaging part.
Do not touch the connector.
| *a | Housing Side Wall |
| *b | Guide |
| *c | 20° or more |
Contact the main body ECU guide against the housing side wall.
Tech Tips
The angle between the junction block and the main body ECU guide should be 20° or more.
| *a | Housing Side Wall |
| *b | Guide |
| *c | Fuse Area |
While aligning the guide with the housing side wall, slide the main body ECU toward the fuse area of the instrument panel junction block.
| *a | A surface |
Slide the main body ECU until it contacts the A surface.
Note
Slide the main body ECU gently.
Do not apply strong impact to the side of the main body ECU.
| *a | A surface |
Rotate the main body ECU while holding it against the junction block A surface (axis of rotation).
| *1 | Main Body ECU |
| *2 | Instrument Panel Junction Block |
| *a | Push Area |
Rotate the main body ECU until it engages with the lock to install it.
Note
When pressing the main body ECU, press the push area as shown in the illustration.
A lock sound will be heard when the main body ECU is engaged.
Do not hit or weight the main body ECU when it engages with the instrument panel junction block.
Tech Tips
If a lock sound is not heard, visually check the lock engagement. Check that the height of the main body ECU and instrument panel junction block match.
INSTALL JUNCTION BLOCK BRACKET
Engage the claw and install the junction block bracket.
INSTALL JUNCTION BLOCK BRACKET
Engage the claw and install the junction block bracket.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Connect the back side connector B indicated as shown in the illustration.
Slide the lever by the arrow indicated as shown in the illustration.
| *a | Lever |
Connect the back side connector A indicated as shown in the illustration.
Engage the claw, 2 clamps and install the instrument panel junction block.
Tighten the 2 bolts.
Connect the main body ECU connector.
Connect the connectors to front side of the instrument panel junction block.
Engage the clamps.
INSTALL INSTRUMENT PANEL WIRE
Engage the clamp and install the instrument panel wire.
Tighten the screw.
INSTALL LOWER NO. 2 INSTRUMENT PANEL FINISH PANEL (for LHD)
INSTALL UPPER INSTRUMENT PANEL SUB-ASSEMBLY (for LHD)
INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY (for RHD)
Tech Tips
Use the same procedure as for the LHD side Click here.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL