PROCEDURE
INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
| *1 | Length |
Using a vernier caliper, measure the exposed brush length.
| Standard exposed length |
|---|
| 9.5 to 11.5 mm (0.374 to 0.453 in.) |
| Minimum exposed length |
|---|
| 4.5 mm (0.177 in.) |
If the exposed length is less than the minimum, replace the generator brush holder assembly.
INSPECT GENERATOR REGULATOR ASSEMBLY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator regulator assembly.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator regulator assembly.
INSPECT GENERATOR DRIVE END FRAME
Check the stator coil for open circuits.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator assembly.
Inspect the stator for ground.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator assembly.
Inspect the bearing.
Make sure that the bearing is not rough or worn. If necessary, replace the generator assembly.
INSPECT GENERATOR HOLDER WITH RECTIFIER
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator holder with rectifier.
INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor for open circuits.
Measure the resistance between the slip rings.
| *1 | Slip Ring |
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the resistance is not as specified, replace the generator rotor assembly.
| *1 | Slip Ring |
| *2 | Rotor |
Check the generator rotor for short circuits.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the generator rotor assembly.
Inspect slip rings.
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
Using a vernier caliper, measure the slip ring diameter.
| Standard diameter |
|---|
| 14.2 to 14.4 mm (0.559 to 0.567 in.) |
| Minimum diameter |
|---|
| 14.0 mm (0.551 in.) |
If the diameter is less than the minimum, replace the generator rotor assembly.