GENERATOR(for TMMF Made) REMOVAL

PROCEDURE


  1. PRECAUTION

    CAUTION:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  3. REMOVE FAN AND GENERATOR V BELT

    Click here

  4. REMOVE GENERATOR ASSEMBLY

    A01VHCZ

    1. Remove the terminal cap.

    2. Separate the connector and 2 harness clamps.

    3. Remove the nut and terminal B.

    4. A01VI83E02

      Remove fan belt adjusting slider fixing bolts A and B and the fan belt adjusting bar assembly.

    5. A01VIFSE02

      Remove fixing bolt B and the generator.