PROCEDURE
INSTALL GENERATOR ASSEMBLY
Install the 2 wire harness clamp brackets to the generator assembly with the 2 bolts.
Temporarily install the generator assembly and generator bracket to the timing chain cover sub-assembly with the 3 bolts.
Tighten the 3 bolts in the sequence shown in the illustration.
Connect the compressor with pulley assembly connector.
Engage the 2 clamps to connect the wire harness to the 2 wire harness clamp brackets.
Connect the wire harness to terminal B with the nut.
Install the terminal cap.
INSTALL FAN AND GENERATOR V BELT
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.