| DTC Code | DTC Name |
|---|---|
| P2769 | Torque Converter Clutch Solenoid Circuit Low |
| P2770 | Torque Converter Clutch Solenoid Circuit High |
DESCRIPTION
Based on the signal received by the shift solenoid valve SL, the ECM uses the shift solenoid valve SLU to control the lock-up clutch pressure.
If there is an open or short in the shift solenoid valve SL circuit, the ECM stops sending current to the malfunctioning shift solenoid valve.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2769 | Torque Converter Clutch Solenoid Circuit Low | While the lock-up is operating, a short is detected in the shift solenoid valve SL circuit 1 time or more consecutively (1 trip detection logic). |
|
Comes on | DTC stored |
| P2770 | Torque Converter Clutch Solenoid Circuit High | While the lock-up is operating, an open is detected in the shift solenoid valve SL circuit 1 time or more consecutively (1 trip detection logic). |
|
Comes on | DTC stored |
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve SL circuit. If there is an open or short in the shift solenoid valve SL circuit, the ECM detects the malfunction, illuminates the MIL and stores a DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Perform initialization after replacing any parts related to the continuously variable transaxle system.
Check that no DTCs are stored after performing initialization.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
| *a | Component without harness connected (Transmission Wire) |
Disconnect the B115 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the B115 transmission wire connector.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the B112*1 or B118*2 ECM connector.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (for LHD) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (for RHD) | ||||||
|---|---|---|---|---|---|---|
|
Connect the B112*1 or B118*2 ECM connector.
*1: for LHD
*2: for RHD
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM INITIALIZATION Click here |