MULTI-MODE MANUAL TRANSAXLE SYSTEM, Diagnostic DTC:P0919

DTC Code DTC Name
P0919 Gear Shift Position Control Error

DESCRIPTION

In the multi-mode manual transaxle system, the transaxle gear is shifted up and down by the TCM using a shift and select actuator. The shift and select actuator assembly consists of two motors (shift motor and select motor), stroke sensors (shift stroke sensor and select stroke sensor) and gears to move the shift and select lever shaft. The shift motor moves the shift and select lever shaft in the shift direction according to the signal from the TCM.

This DTC is set in accordance with the stroke speed of the shift and select actuator or the difference between the target shift position and the actual shift position. Therefore, if malfunctions occur in the shift stroke sensor or the shift motor circuit, the DTCs relating to the sensor or motor circuit open/short (DTC P0915, P0916, P0917 and/or P0920) are set before this DTC is set.

DTC No. DTC Detection Condition Trouble Area
P0919

The TCM detects the following conditions simultaneously for 2.0 seconds:

(1-trip detection logic)


  1. Shift motor current is 20 A or more, -20 A or less.

  2. Difference between target shift position and actual shift position is 0.3 mm (0.0118 in.) or more.

  3. Shift and select actuator movement is 122 mm/sec (4.8 in./sec) or less.


  • Shift stroke sensor

  • Shift and select actuator assembly (shift motor)

  • TCM

  • Transaxle assembly

WIRING DIAGRAM

A01VHPLE19
*a Sub
*b Main
*c Shift Stroke Sensor
*d Shift and Select Actuator Assembly (Shift Motor)

CAUTION / NOTICE / HINT

Note

In shift stroke sensor or shift and select actuator assembly replacement, perform the [Initialization and Learning] procedure (See page ) and [Synchronization Position Calibration] procedure Click here after installing the sensor or actuator assembly. If the sensor or actuator is installed without performing [Initialization and Learning] and [Synchronization Position Calibration], it may cause driving performance degradation or system component breakage.

Tech Tips

If the symptom still occurs even after checking the following parts for dirt, wear, and defects and replacing the defective parts, replace the TCM.


  • Synchronizer rings

  • Shift forks

  • Hub sleeves

PROCEDURE


  1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (TARGET GEAR POSITION CONTROL)


    1. Remove the shift and select actuator assembly Click here.

    2. Connect the shift and select actuator assembly connector.

    3. Connect the intelligent tester to the DLC3.

    4. Turn the ignition switch to ON.

    5. Turn the tester on.

    6. Enter the following menus: Powertrain / Multi-Mode M/T / Active Test / Target Gear Position Control.

      OK
      Shift and select actuator moves smoothly in accordance with the tester operation.

    NG
    OK
  2. INSPECT SHIFT STROKE SENSOR


    1. Remove the shift stroke sensor.

    2. A01VLTWE19
      Text In Illustration
      *1 Sensor Arm
      *a

      Component without harness connected

      (Shift Stroke Sensor)

      *b Main

      Measure the voltage between the terminals of the shift stroke sensor connector (main).


      1. Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.

      2. Connect the batteries in series.

      3. Connect the positive battery terminal to sensor terminal 3 (VCS1), and the negative battery terminal to sensor terminal 2 (E2S1).

      4. Measure the voltage according to the value(s) in the table below.

        Standard Voltage (combined dry cell battery voltage of 4.5 V)
        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition
        1 (VSS1) - 2 (E2S1) 55° Approximately 4.05 V
        Approximately 2.25 V
        -55° Approximately 0.45 V
        Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition
        1 (VSS1) - 2 (E2S1) 55° Approximately 4.5 V
        Approximately 2.5 V
        -55° Approximately 0.5 V
    3. A01VLTWE20
      Text In Illustration
      *1 Sensor Arm
      *a

      Component without harness connected

      (Shift Stroke Sensor)

      *b Sub

      Measure the voltage between the terminals of the shift stroke sensor connector (Sub).


      1. Connect the positive battery terminal to sensor terminal 6 (VCS2), and the negative battery terminal to sensor terminal 5 (E2S2).

      2. Measure the voltage according to the value(s) in the table below.

        Standard Voltage (combined dry cell battery voltage of 4.5 V)
        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition
        4 (VSS2) - 5 (E2S2) 55° Approximately 4.05 V
        Approximately 2.25 V
        -55° Approximately 0.45 V
        Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition
        4 (VSS2) - 5 (E2S2) 55° Approximately 4.5 V
        Approximately 2.5 V
        -55° Approximately 0.5 V

        Note


        • Do not apply more than 6 V

        • Do not use a sensor which has been dropped.


    NG
    OK
  3. INSPECT TCM (MSF TERMINAL VOLTAGE)


    1. Turn the ignition switch to ON.

    2. A01VESTE01
      Text in Illustration
      *a

      Component with harness connected

      (TCM)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A46-4 (MSF+) - Body ground Ignition switch ON 4.0 to 7.0 V
      A46-3 (MSF-) - Body ground Ignition switch ON 4.0 to 7.0 V
    3. Turn the ignition switch off.


    NG
    OK
  4. INSPECT TRANSAXLE ASSEMBLY


    1. Remove the transaxle assembly Click here.

    2. Check for dirt, wear and defects in the gear shift mechanical system (synchronizer rings, shift forks, hub sleeves, etc.).

      OK
      No defective parts in the transaxle assembly.

    NG
    OK
  5. REPLACE TCM


    1. Replace the TCM Click here.


    NEXT
  6. PERFORM INITIALIZATION


    1. Perform the initialization and learning for multi-mode manual transaxle system Click here.


    NEXT
  7. CHECK TERMINAL CONDITION (TCM)


    1. Disconnect the TCM connector.

    2. Check the connections of the TCM connector.

      OK
      The TCM and wire harness connectors and connector terminals are connected securely and are not bent, rusted, or damaged.

    NG
    OK
  8. CHECK SHIFT MOTOR CIRCUIT


    1. A01VF80E01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to TCM)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A46-4 (MSF+) - A46-3 (MSF-) Always Below 10 Ω
      A46-4 (MSF+) - Body ground Always 10 kΩ or higher
      A46-3 (MSF-) - Body ground Always 10 kΩ or higher

    NG
    OK
  9. REPLACE TCM


    1. Replace the TCM Click here.


    NEXT
  10. PERFORM INITIALIZATION


    1. Perform the initialization and learning for multi-mode manual transaxle system Click here.


    NEXT
  11. CHECK TERMINAL CONDITION (SHIFT MOTOR)


    1. Disconnect the shift motor connector.

    2. Check the connections of the shift motor connector.

      OK
      The shift motor and wire harness connectors and connector terminals are connected securely and are not bent, rusted, or damaged.

    NG
    OK
  12. CHECK HARNESS AND CONNECTOR (TCM - SHIFT MOTOR)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A46-4 (MSF+) - B58-2 Always Below 1 Ω
      A46-3 (MSF-) - B58-1 Always Below 1 Ω
      A46-4 (MSF+) or B58-2 - Body ground Always 10 kΩ or higher
      A46-3 (MSF-) or B58-1 - Body ground Always 10 kΩ or higher

    NG
    OK
  13. INSPECT SHIFT AND SELECT ACTUATOR ASSEMBLY (SHIFT MOTOR)


    1. A01VGYOE01
      Text In Illustration
      *a

      Component without harness connected

      (Shift and Select Actuator Assembly (Shift Motor))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always Below 10 Ω
      1 - Body ground Always 10 kΩ or higher
      2 - Body ground Always 10 kΩ or higher

    OK
    NG
  14. REPLACE SHIFT AND SELECT ACTUATOR ASSEMBLY


    1. Replace the shift and select actuator assembly Click here.


    NEXT
  15. PERFORM INITIALIZATION


    1. Perform the initialization and learning for multi-mode manual transaxle system Click here.


    NEXT
  16. REPLACE SHIFT STROKE SENSOR


    1. Replace the shift stroke sensor Click here.


    NEXT
  17. PERFORM INITIALIZATION


    1. Perform the initialization and learning for multi-mode manual transaxle system Click here.


    NEXT