PROCEDURE
INSTALL OIL PUMP WITH MOTOR ASSEMBLY
Temporarily install a new oil pump with motor assembly to the continuously variable transaxle assembly with the 3 bolts.
Note
Make sure that the O-ring is installed to the oil pump with motor assembly.
Make sure that the O-ring is not moved out of place when installing the oil pump with motor assembly.
To prevent the O-ring from being damaged, do not move the oil pump with motor assembly laterally with it contacting the continuously variable transaxle assembly.
Tighten the 3 bolts.
Install the wire harness clamp bracket to the oil pump with motor assembly with the bolt.
Connect the oil pump with motor assembly connector.
ADD CONTINUOUSLY VARIABLE TRANSAXLE FLUID
AIR BLEED OIL PUMP WITH MOTOR ASSEMBLY
INSPECT FOR CONTINUOUSLY VARIABLE TRANSAXLE FLUID LEAK
INSTALL ENGINE UNDER COVER LH