OIL PUMP ASSEMBLY INSTALLATION

PROCEDURE


  1. INSTALL OIL PUMP WITH MOTOR ASSEMBLY


    1. Temporarily install a new oil pump with motor assembly to the continuously variable transaxle assembly with the 3 bolts.

      Note


      • Make sure that the O-ring is installed to the oil pump with motor assembly.

      • Make sure that the O-ring is not moved out of place when installing the oil pump with motor assembly.

      • To prevent the O-ring from being damaged, do not move the oil pump with motor assembly laterally with it contacting the continuously variable transaxle assembly.

    2. Tighten the 3 bolts.

      Torque:
      22 N*m  { 224 kgf*cm, 16 ft.*lbf }
    3. Install the wire harness clamp bracket to the oil pump with motor assembly with the bolt.

      Torque:
      12.8 N*m  { 131 kgf*cm, 9 ft.*lbf }
    4. Connect the oil pump with motor assembly connector.

  2. ADD CONTINUOUSLY VARIABLE TRANSAXLE FLUID

    Click here

  3. AIR BLEED OIL PUMP WITH MOTOR ASSEMBLY

    Click here

  4. INSPECT FOR CONTINUOUSLY VARIABLE TRANSAXLE FLUID LEAK

  5. INSTALL ENGINE UNDER COVER LH

    Click here