GLOW PLUG(w/ DPF) ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT GLOW PLUG ASSEMBLY


    1. Remove the glow plug connector Click here.

    2. Check the resistance.


      1. A01VGI9

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Glow plug terminal - Ground 20°C (68°F) 0.28 Ω or higher

        Note


        • Do not damage the glow plug assembly as this could cause an open circuit or shorten the life of the glow plug assemblies.

        • Prevent oil and fuel from spraying onto the glow plug assemblies when cleaning.

        • Wipe any oil off the terminal and the Bakelite washer with a dry cloth if they are stained with oil during the inspection.

        If the result is not as specified, replace the glow plug assembly.

    3. Install the glow plug connector Click here.