THERMOSTAT INSPECTION

PROCEDURE


  1. INSPECT THERMOSTAT

    A01VJVR

    Tech Tips

    The valve opening temperature is inscribed on the thermostat.


    1. A01VIOT

      Check the operation.


      1. Immerse the thermostat in water and gradually heat the water.

        CAUTION:

        Make sure not to burn yourself.

      2. Check the valve opening temperature of the thermostat.

        Valve opening temperature
        78 to 82°C (172 to 180°F)

        If the valve opening temperature is not as specified, replace the thermostat.

    2. A01VFD2E03
      Text in Illustration
      *a Valve Lift

      Check the valve lift.

      Valve lift
      8.5 mm (0.33 in.) or more at 93°C (199°F)
    3. Check that the valve is fully closed when the thermostat is at low temperatures (below 75°C (167°F)).

      If the valve is not fully closed, replace the thermostat.