PURGE VALVE INSPECTION

PROCEDURE


  1. INSPECT PURGE VALVE (PURGE VSV)


    1. Check the resistance.


      1. A0046RJC10
        *a

        Component without harness connected

        (Purge Valve (Purge VSV))

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 20°C (68°F) 23 to 26 Ω

        If the result is not as specified, replace the purge valve (purge VSV).

    2. Check the operation.


      1. A0049KZC02
        *a Port (E)
        *b Port (F)
        *c Air

        Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

        OK
        Measurement Condition Specified Condition
        Battery voltage applied between terminals 1 and 2 Air flows from port (F)
        Battery voltage not applied between terminals 1 and 2 Air does not flow

        If the result is not as specified, replace the purge valve (purge VSV).