PROCEDURE
CHECK CHARCOAL CANISTER
Inspect the ventilation of the canister.
| *a | Port A |
| *b | Port B |
| *c | Air |
Open the fuel tank cap, apply compressed air into port B and check that the air flows out from port A.
| OK |
|---|
| The air flows out from the port A. |
Inspect the check valve.
| *a | Port A |
| *b | Port B |
| *c | Air |
Open the fuel tank cap, close the port A, and apply the compressed air from the port B.
| OK |
|---|
| Air does not flow at first. By gradually increasing the pressure, air flows when the pressure in the port reaches the specified level. |
| *a | Port A |
| *b | Port B |
Open the fuel tank cap, close the port A, and apply a vacuum from the port B, using a vacuum pump.
| OK |
|---|
| The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches the specified level. |