PURGE VALVE INSPECTION

PROCEDURE


  1. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY


    1. A01VF0HE04
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Vacuum Switching Valve Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω

      If the result is not as specified, replace the No. 1 vacuum switching valve assembly.

    2. Check operation of the No. 1 vacuum switching valve assembly.


      1. A01VI8QE03
        Text in Illustration
        *1 Port E
        *2 Port F
        A01VL3H Air

        Check that air does not flow from port E to port F.

      2. A01VJ80E03
        Text in Illustration
        *1 Port E
        *2 Port F
        A01VL3H Air

        Apply battery voltage across the terminals.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the No. 1 vacuum switching valve assembly.