PCV VALVE REMOVAL

PROCEDURE


  1. SEPARATE VENTILATION HOSE


    1. A01VIMX

      Disconnect the ventilation hose from the ventilation valve sub-assembly.

  2. REMOVE VENTILATION VALVE SUB-ASSEMBLY


    1. A01VHGBE02
      Text in Illustration
      *1 Ventilation Valve Sub-assembly
      *2 Ventilation System Grommet

      Remove the ventilation valve sub-assembly from the cylinder head cover.

  3. REMOVE VENTILATION SYSTEM GROMMET


    1. Remove the Ventilation system grommet from the cylinder head cover.