Click here

PURGE VALVE INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT DUTY VACUUM SWITCHING VALVE


    1. Check the resistance.


      1. A01VKSOE03

        Measure the resistance according to the value(s) in the table below.

        Table 1. Text in Illustration
        *a

        Component without harness connected

        (Duty Vacuum Switching Valve)

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 20°C (68°F) 23 to 26 Ω

        If the result is not as specified, replace the duty vacuum switching valve.

    2. Check the operation.


      1. A01VHK7E03

        Check that air does not flow from port E to port F.

        Table 2. Text in Illustration
        *a

        Component without harness connected

        (Duty Vacuum Switching Valve)

        *b Air
        OK
        Condition Specified Condition
        No continuity There is no air flow
      2. A01VLAQE04

        Apply battery voltage across the terminals to check that air flows from port E to port F.

        Table 3. Text in Illustration
        *a

        Component without harness connected

        (Duty Vacuum Switching Valve)

        *b Air
        OK
        Condition Specified Condition
        With continuity There is air flow