PROCEDURE
INSTALL ELECTRIC EGR CONTROL VALVE ASSEMBLY
Install a new EGR valve gasket onto the intake air connector.
| *1 | EGR Control Valve |
| *a | View A |
| *b | Upper |
| *c | View B |
Apply adhesive to the 2 or 3 end threads of the 2 bolts.
| Adhesive |
|---|
| Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent. |
Install the electric EGR control valve assembly with the 2 bolts.
Connect the No. 3 water by-pass hose to the electric EGR control valve assembly.
Connect the No. 4 water by-pass hose to the electric EGR control valve assembly.
INSTALL EGR WITH COOLER PIPE SUB-ASSEMBLY
INSPECT FOR EXHAUST GAS LEAK
INITIALIZATION
When replacing the electric EGR control valve assembly, perform initialization Click here.