PROCEDURE
INSPECT SUPPLY PUMP ASSEMBLY
| *1 | Fuel Metering Unit |
| *a | Component without harness connected (Supply Pump Assembly) |
Check the resistance of the fuel metering unit.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the supply pump assembly.
| *a | Component without harness connected (Supply Pump Assembly) |
Check the resistance of the fuel temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the supply pump assembly.