INTAKE AIR TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT INTAKE AIR TEMPERATURE SENSOR


    1. Partially immerse the sensor in water and warm up the water.

      A01VERSE01
    2. Measure the resistance according to the value(s) in the table below.

      Text in Illustration
      *a

      Component without harness connected

      (Intake Air Temperature Sensor)

      *b Acceptable
      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Approximately 20°C (68°F) 2.21 to 2.65 kΩ
      Approximately 60°C (140°F) 0.55 to 0.61 kΩ

      Note

      When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.

      If the result is not as specified, replace the sensor.