MASS AIR FLOW METER(w/ DPF) INSTALLATION

CAUTION / NOTICE / HINT

Tech Tips

Perform "Inspection After Repairs" after replacing the mass air flow meter.

PROCEDURE


  1. INSTALL MASS AIR FLOW METER


    1. Install the mass air flow meter to the air cleaner cap sub-assembly with the 2 screws.

      Torque:
      1.6 N*m  { 16 kgf*cm, 14 in.*lbf }

      Note


      • If the mass air flow meter has been struck or dropped, replace it.

      • If reusing the mass air flow meter inspect the O-ring.

      • Make sure that the O-ring is not cracked or jammed during installation.

    2. Connect the mass air flow meter connector.