MASS AIR FLOW METER INSPECTION

PROCEDURE


  1. INSPECT MASS AIR FLOW METER


    1. A01VJBSE02
      Text in Illustration
      *a

      Component without harness connected

      (Mass Air Flow Meter)

      *b Acceptable

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (THA) - 5 (E2) -20°C (-4°F) 12.5 to 16.9 kΩ
      20°C (68°F) 2.19 to 2.67 kΩ
      60°C (140°F) 0.50 to 0.68 kΩ

      If the result is not as specified, replace the mass air flow meter.