| DTC Code | DTC Name |
|---|---|
| P245A | Open in Exhaust Gas Recirculation Cooler Bypass Control Circuit |
| P245C | EGR Cooler Bypass Control Circuit Low |
| P245D | EGR Cooler Bypass Control Circuit High |
DESCRIPTION
The ECM controls the No. 1 vacuum switching valve assembly (EGR cooler bypass valve VSV) to open and close the EGR cooler bypass valve.
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 15 seconds or more | Open or short in No. 1 vacuum switching valve assembly (EGR cooler bypass valve VSV) control circuit for 3 seconds (2 trip detection logic) |
|
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 15 seconds or more | Ground short in No. 1 vacuum switching valve assembly (EGR cooler bypass valve VSV) control circuit for 3 seconds (2 trip detection logic) |
|
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 15 seconds or more | Battery short in No. 1 vacuum switching valve assembly (EGR cooler bypass valve VSV) control circuit for 3 seconds (2 trip detection logic) |
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
When replacing the ECM, the ECM needs Registration and Initialization Click here.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Tech Tips
When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the intelligent tester. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the tester display.
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
PROCEDURE
INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (EGR COOLER BYPASS VALVE VSV) (OPERATION)
| *a | VSV ON |
| *b | VSV OFF |
Remove the No. 1 vacuum switching valve assembly.
Apply the battery voltage across the terminals.
Check that the air flows.
| OK | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (EGR COOLER BYPASS VALVE VSV) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (NO. 1 VACUUM SWITCHING VALVE ASSEMBLY - ECM)
Disconnect the No. 1 vacuum switching valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (NO. 1 VACUUM SWITCHING VALVE ASSEMBLY - NO. 1 INTEGRATION RELAY)
Disconnect the No. 1 vacuum switching valve assembly connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE)
| *a | Front view of wire harness connector (to No. 1 Vacuum Switching Valve Assembly) |
Disconnect the No. 1 vacuum switching valve assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
CHECK ECM POWER SOURCE CIRCUIT Click here |
| OK |
|
REPLACE ECM
Replace the ECM Click here.
| NEXT |
|
CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED Click here |
CHECK ECM POWER SOURCE CIRCUIT
Check the ECM power source circuit Click here.
| NEXT |
|
CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED Click here |
REPLACE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (EGR COOLER BYPASS VALVE VSV)
Replace the No. 1 vacuum switching valve assembly Click here.
| NEXT |
|
CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED Click here |
REPAIR OR REPLACE HARNESS OR CONNECTOR
| NEXT |
|
CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester on.
Clear the DTCs Click here.
Turn the ignition switch off and wait for 30 seconds or more.
Turn the ignition switch to ON and wait for 15 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC / Pending.
Confirm that the pending DTC is not output again.
| NEXT |
|
END |