ECD SYSTEM(w/ DPF) Cranking Holding Function Circuit

DESCRIPTION


WIRING DIAGRAM

A01VHHWE02

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

  • When replacing the ECM, the ECM needs Registration and Initialization Click here.

Tech Tips


  • When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the intelligent tester. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the intelligent tester display.

  • This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table Click here.

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.

    5. Check the value displayed on the intelligent tester when the ignition switch is turned to the ON and START positions.

      OK
      Ignition Switch Position Starter Signal
      ON OFF
      START ON

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (ECM - STARTER RELAY ASSEMBLY HOLDER)


    1. Disconnect the A59 ECM connector.

    2. Remove the starter relay assembly from the engine room relay block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A59-6 (STA) - 2 (Starter relay holder) Always Below 1 Ω

    OK
    NG