Click here

HEATED OXYGEN SENSOR(for Sensor 2) INSPECTION

Click here
Click here Click here

PROCEDURE


  1. Click here

    INSPECT NO. 2 HEATED OXYGEN SENSOR


    1. Check the resistance.


      1. A01VK69E06

        Measure the resistance according to the value(s) in the table below.

        Table 1. Text in Illustration
        *a

        Component without harness connected

        (No. 2 Heated Oxygen Sensor)

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (+B) - 2 (HT1B) 20°C (68°F) 2.7 to 3.3 Ω
        2 (HT1B) - 3 (E1) Always 10 kΩ or higher

        If the result is not as specified, replace the No. 2 heated oxygen sensor.