PROCEDURE
INSTALL HEATED OXYGEN SENSOR
Using SST, install the heated oxygen sensor onto the exhaust manifold.
Note
If a component has been dropped or subjected to a strong impact, replace it.
Tech Tips
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values Click here.
Connect the connector of the heated oxygen sensor.
Engage the clamp and connect the heated oxygen sensor wire to the wire harness clamp bracket.
INSPECT FOR EXHAUST GAS LEAK