Click here

MANIFOLD ABSOLUTE PRESSURE SENSOR INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR


    1. A01VITWE02

      Measure the resistance according to the value(s) in the table below.

      Table 1. Text in Illustration
      *a

      Component without harness connected

      (Manifold Absolute Pressure Sensor)

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (E2) - 4 (THA) -20°C (-4°F) 14.6 to 17.8 kΩ at -20°C (-4°F)
      20°C (68°F) 2.21 to 2.69 kΩ at 20°C (68°F)
      80°C (176°F) 0.29 to 0.354 kΩ at 80°C (176°F)

      If the resistance is not as specified, replace the manifold absolute pressure sensor.