CAMSHAFT OIL CONTROL VALVE REMOVAL

PROCEDURE


  1. DISCONNECT VENTILATION HOSE


    1. A01VEW5

      Loosen the hose clip and disconnect the ventilation hose.

  2. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    1. A01VF72

      Disconnect the connector of the camshaft timing oil control valve assembly.

    2. Remove the bolt and remove the camshaft timing oil control valve assembly from the cylinder head sub-assembly.

      Note

      If a component has been dropped or subjected to a strong impact, replace it.