STOP AND START SERVICE DATA

Vacuum sensor Standard voltage A33-3 (VC) - A33-1 (E2)

4.75 to 5.25 V

Ignition Switch ON

Engine stop and start ECU Standard voltage F92-13 (PB) - F92-3 (BRE2)

3.4 to 3.8 V

Atmospheric pressure

Brake boost pressure Standard Pressure

Changes by 20 kPa (150 mmHg, 6 in.Hg) or more


  • Ignition switch ON

  • Brake pedal depressed 5 times

Cooler thermistor Standard resistance 1 - 2

9.4 to 10.5 kΩ

10°C (50°F)

7.5 to 8.3 kΩ

15°C (59°F)

6.0 to 6.5 kΩ

20°C (68°F)

4.8 to 5.2 kΩ

25°C (77°F)

3.8 to 4.2 kΩ

30°C (86°F)

3.1 to 3.4 kΩ

35°C (95°F)

2.5 to 2.8 kΩ

40°C (104°F)

2.0 to 2.3 kΩ

45°C (113°F)

1.6 to 2.0 kΩ

50°C (122°F)

1.3 to 1.6 kΩ

55°C (131°F)

1.1 to 1.4 kΩ

60°C (140°F)

Warning canceling switch Standard Resistance 6 (ECU) - 3 (E)

Below 1 Ω

Pushed

10 kΩ or higher

Not pushed

Battery positive (+) - Terminal 5 (ILL+) Battery negative (-) - Terminal 4 (ILL-) Illuminates
Oil pump motor relay Standard resistance 3 - 5

10 kΩ or higher

Battery voltage not applied

Below 1 Ω

Battery voltage applied to terminals 1 and 2

Oil pump with motor assembly

Battery positive (+) → Terminal 4 (+B)

Battery negative (-) → Terminal 3 (SI)

Battery negative (-) → Terminal 1 (GND)

Operating sound can be heard