LIGHTING (EXT) SERVICE DATA

Headlight dimmer relay

3 - 4: Below 1 Ω (Voltage is not applied between terminals 1 and 2)

3 - 4: 10 kΩ or higher (Apply the battery voltage between terminals 1 and 2)

3 - 5 : 10 kΩ or higher (Voltage is not applied between terminals 1 and 2)

3 - 5 : Below 1 Ω (Apply the battery voltage between terminals 1 and 2)

Headlight relay

3 - 5 : 10 kΩ or higher (Voltage is not applied between terminals 1 and 2)

3 - 5 : Below 1 Ω (Apply the battery voltage between terminals 1 and 2)

FR fog light relay

3 - 5 : 10 kΩ or higher (Voltage is not applied between terminals 1 and 2)

3 - 5 : Below 1 Ω (Apply the battery voltage between terminals 1 and 2)

Stop light switch assembly

(for LED Type Stop Light)

A101-1 (B) - A101-3 (GND) : 11 to 14 V (Always)

A101-2 (L) - A101-3 (GND) : 11 to 14 V (Ignition switch ON (IG))

A101-2 (L) - A101-3 (GND) : 11 to 14 V (Ignition switch off)

A101-3 (GND) - Body ground : Below 1 Ω (Always)

A101-2 (L) - A101-3 (GND) : Below 1 V (Ignition switch off, brake pedal not depressed)

A101-2 (L) - A101-3 (GND) : 11 to 14 V (Ignition switch off, brake pedal depressed)

Stop light switch assembly

(for Bulb Type Stop Light)

1 - 2 : Below 1 Ω (Not pushed)

1 - 2 : 10 kΩ or higher (pushed)

3 - 4 : 10 kΩ or higher (Not pushed)

3 - 4 : Below 1 Ω (pushed)