2NR-FKE COOLING SERVICE DATA

COOLANT
Capacity Classification
for CVT 5.7 liters (6.0 US qts, 5.0 Imp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).
for Manual Transaxle 5.5 liters (5.8 US qts, 4.8 Imp. qts)
Thermostat
Condition Specified Condition
Standard valve opening temperature 86 to 90°C (187 to 194°F)
Standard valve lift 8.5 mm (0.335 in.) or more at 100°C (212°F)
Cooling Fan Motor
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 10.2 to 14.4 A
Cooling Fan Resistor
Item Tester Connection Condition Specified Condition
Cooling fan motor 1 - 2 Battery voltage applied at 20°C (68°F) 1.17 to 1.43 Ω
Relay
Item Tester Connection Condition Specified Condition
Cooling fan relay 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
No. 2 cooling fan relay 3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Radiator
Item Condition Specified Condition
Radiator Cap Sub-assembly

Standard pressure

(for brand-new radiator cap sub-assembly)

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.4 to 17.7 psi)

Minimum pressure

(for used radiator cap sub-assembly)

78 kPa (0.8 kgf/cm2, 11.3 psi)