HAZARD WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    1. B004Y2ZC01
      *a

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      Inspect the hazard warning signal switch assembly.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        6 - 3 Hazard warning signal switch OFF 10 kΩ or higher
        Hazard warning signal switch ON Below 50 Ω
        If the result is not as specified, replace the hazard warning signal switch assembly.
    2. B004Y2ZC02
      *a

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      Check the illumination.


      1. Apply battery voltage to the connector and check the illumination conditions.

        OK
        Tester Connection Specified Condition

        7 - Battery positive (+)

        1 - Battery negative (-)

        Illuminates
        If the result is not as specified, replace the hazard warning signal switch assembly.