INTERIOR ILLUMINATION LIGHT(for Meter Cluster) INSPECTION

PROCEDURE


  1. INSPECT METER HOOD ILLUMINATION LIGHT ASSEMBLY


    1. B004YIOC01
      *a

      Component without harness connected

      (Meter Hood Illumination Light Assembly)

      Inspect the meter hood illumination light assembly.

      Apply auxiliary battery voltage to the connector and check the light illumination condition.

      OK
      Tester Connection Specified Condition

      G94-3 (ILL+) - Auxiliary battery positive (+)

      G94-4 (ILL-) - Auxiliary battery negative (-)

      Meter hood illumination light assembly LH illuminates

      G94-1 (ILL+) - Auxiliary battery positive (+)

      G94-2 (ILL-) - Auxiliary battery negative (-)

      Meter hood illumination light assembly RH illuminates

      If the result is not as specified, replace the meter hood illumination light assembly.