LIGHTING SYSTEM ACC Signal Circuit

DESCRIPTION

This circuit detects the power switch on (ACC) or off condition, and sends it to the main body ECU (multiplex network body ECU).

WIRING DIAGRAM

B004TAWE01

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses for circuits related to this system before performing the following procedure.

  • Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.

PROCEDURE


  1. CHECK FOR DTC (ENTRY AND START SYSTEM [for Start Function])


    1. Check for DTCs.

      Click here


      Body Electrical > Power Source Control > Trouble Codes
      OK
      Entry and start system (for Start Function) DTCs are not output.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. READ VALUE USING GTS


    1. Read the Data List according to the display on the GTS.

      Click here


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      ACC SW Power switch on (ACC) signal OFF or ON

      OFF: Power switch off

      ON: Power switch on (ACC)

      "ON" is also displayed for this item when the power switch is on (IG).

      Body Electrical > Main Body > Data List
      Tester Display
      ACC SW
      OK
      Normal conditions listed above are displayed.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  3. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BATTERY AND BODY GROUND)


    1. B004X3RC05
      *a

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Disconnect the instrument panel junction block assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      5K-1 - Body ground Power switch off 11 to 14 V
      5D-17 - Body ground Power switch on (ACC) 11 to 14 V
      Power switch off Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      5K-1 - Body ground Power switch off 11 to 14 V
      5D-18 - Body ground Power switch on (ACC) 11 to 14 V
      Power switch off Below 1 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      5D-6 - Body ground Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      5D-7 - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. Remove the instrument panel junction block assembly.

      Click here

      B004UNNC06
      *a

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      - -
    2. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

      Click here

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      5K-1 - A-30 (ACC) Auxiliary battery not connected to 5D-17 and 5D-6 10 kΩ or higher

      Auxiliary battery positive (+) → 5D-17

      Auxiliary battery negative (-) → 5D-6

      Below 1 Ω
      5D-6 - A-11 (GND1) Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      5K-1 - A-30 (ACC) Auxiliary battery not connected to 5D-18 and 5D-7 10 kΩ or higher

      Auxiliary battery positive (+) → 5D-18

      Auxiliary battery negative (-) → 5D-7

      Below 1 Ω
      5D-7 - A-11 (GND1) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG