WIRELESS DOOR LOCK CONTROL SYSTEM No Answer-Back

DESCRIPTION

In some cases, wireless door lock control functions are normal but the hazard warning light and/or wireless door lock buzzer answer-back function does not operate. In such cases, hazard warning light and wireless door lock buzzer signal output from the main body ECU (multiplex network body ECU) may be malfunctioning.

WIRING DIAGRAM

B004V91E05

CAUTION / NOTICE / HINT

Note


  • Before performing the inspection, check that DTC B1242 (wireless door lock control) is not output.

    Click here

  • If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.

PROCEDURE


  1. CHECK CUSTOMIZE SETTING


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Customize Setting / Wireless Door Lock.

    5. Select the setting by referring to the table below.


      Wireless Door Lock
      Tester Display Description Default Setting ECU
      Hazard Answer Back

      When the doors are locked by wireless operation, the hazard warning lights flash once.

      When the doors are unlocked by wireless operation, the hazard warning lights flash twice.

      ON 0:OFF,1:ON Main body ECU (Multiplex network body ECU)
      Wireless Buzzer Resp Wireless door lock buzzer response ON 0:OFF,1:ON Main body ECU (Multiplex network body ECU)
      Wireless Buzzer Vol Wireless door lock buzzer volume Level5 0000:Level7,0001:Level6,0010:Level5,0011:Level4,0100:Level3,0101:Level2,0110:Level1,0111:Level0 Main body ECU (Multiplex network body ECU)
      Result
      Result Proceed to
      Both items are ON and except Level 0 A
      Either item is OFF or Level 0 B

    B
    A
  2. CHECK WIRELESS DOOR LOCK CONTROL FUNCTIONS


    1. Check the wireless door lock control function using the electrical key transmitter sub-assembly.

      Click here

      Result
      Result Proceed to
      Wireless door lock/unlock operates properly. A
      Wireless door lock/unlock does not operate properly. B

    B
    A
  3. READ VALUE USING GTS (FR Door Lock Pos, FL Door Lock Pos, RR Door Lock Pos, RL Door Lock Pos)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      FR Door Lock Pos Front door RH unlock detection switch signal LOCK or UNLOCK

      LOCK: Front door RH locked

      UNLOCK: Front door RH unlocked

      -
      FL Door Lock Pos Front door LH unlock detection switch signal LOCK or UNLOCK

      LOCK: Front door LH locked

      UNLOCK: Front door LH unlocked

      -
      RR-Door Lock Pos SW Rear door RH unlock detection switch signal OFF or ON

      OFF: Rear door RH locked

      ON: Rear door RH unlocked

      -
      RL-Door Lock Pos SW Rear door LH unlock detection switch signal OFF or ON

      OFF: Rear door LH locked

      ON: Rear door LH unlocked

      -

      Body Electrical > Main Body > Data List
      Tester Display
      FR Door Lock Pos
      FL Door Lock Pos
      RR-Door Lock Pos SW
      RL-Door Lock Pos SW
      OK
      The GTS display changes correctly in response to the lock/unlock operation.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK WIRELESS ANSWER-BACK OPERATION


    1. Check the wireless answer-back operation using the electrical key transmitter sub-assembly.

      Click here

      Result
      Result Proceed to
      Only wireless door lock buzzer answer-back does not occur. A
      Only hazard warning light answer-back does not occur. B

    B
    A
  5. PERFORM ACTIVE TEST USING GTS (Wireless Buzzer)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Active Test.

    5. Perform Active Test according to the display on the GTS.


      Body Electrical > Main Body > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Wireless Buzzer Wireless door lock buzzer OFF/ON -

      Body Electrical > Main Body > Active Test
      Tester Display
      Wireless Buzzer
      Result
      Result Proceed to
      Wireless buzzer does not sound A
      Wireless buzzer sounds B

    B
    A
  6. CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


    1. Disconnect the A7 wireless door lock buzzer connector.

    2. Perform the Active Test using the GTS and sound the wireless door lock buzzer.


      Body Electrical > Main Body > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Wireless Buzzer Wireless door lock buzzer OFF/ON -

      Body Electrical > Main Body > Active Test
      Tester Display
      Wireless Buzzer
    3. While performing the Active Test, measure the voltage between the terminals of the wireless door lock buzzer.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A7-1 (B) - A7-2 (E) Active Test Wireless Buzzer ON

      Pulse generation

      (frequency: 2 kHz, high voltage: 11 to 14 V, low voltage: below 1 V)

      Active Test Wireless Buzzer OFF Below 1 V
      Result
      Proceed to
      OK
      NG

    OK
    NG
  7. CHECK HARNESS AND CONNECTOR (WIRELESS DOOR LOCK BUZZER - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND BODY GROUND)


    1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

      Click here

    2. Disconnect the A7 wireless door lock buzzer connector.

    3. Reconnect the 5F instrument panel junction block assembly connector.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A7-1 (B) - A-21 (BZR) Always Below 1 Ω
      A7-2 (E) - Body ground Always Below 1 Ω
      A7-1 (B) or A-21 (BZR) - Other terminals and body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  8. CHECK HARNESS AND CONNECTOR (WIRELESS DOOR LOCK BUZZER - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. Disconnect the 5F instrument panel junction block assembly connector.

    2. Disconnect the A7 wireless door lock buzzer connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A7-1 (B) - 5F-31 Always Below 1 Ω
      A7-1 (B) or 5F-31 - Other terminals and body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  9. CHECK HAZARD WARNING LIGHTS OPERATION


    1. Check that the hazard warning lights blink when the hazard warning signal switch is pressed.

      OK
      Hazard warning lights blink.
      Result
      Proceed to
      OK
      NG

    OK
    NG