| *a | Hybrid Vehicle Control ECU Assembly | - | - |
The standard normal voltage between each pair of hybrid vehicle control ECU assembly terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the hybrid vehicle control ECU assembly terminal locations.
| Terminal No. (Symbol) | Wiring Color | Input/Output | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|---|
| A77-28 (HMCH) - G92-6 (E1) | G - W-B | IN/OUT | CAN Communication signal | Power switch on (IG) | Pulse generation (Waveform 1) |
| A77-1 (MREL) - G92-6 (E1) | G*1 - W-B LG*2 - W-B |
OUT | Main relay | Power switch on (IG) | 11 to 14 V |
| A76-12 (LIN3) - G92-6 (E1) | V - W-B | IN/OUT | LIN communication signal | Power switch on (READY) | Pulse generation |
| A77-20 (HMCL) - G92-6 (E1) | R - W-B | IN/OUT | CAN Communication signal | Power switch on (IG) | Pulse generation (Waveform 1) |
*1: for LHD
*2: for RHD
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: A77-28 (HMCH) - G92-6 (E1) CH2: A77-20 (HMCL) - G92-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Power switch on (IG) |
The waveform will vary depending on the content of the digital communication (digital signal).