Click here

CHARGING SYSTEM TERMINALS OF ECU

Click here
Click here
Click here
  1. B004SYOC72
    *a Hybrid Vehicle Control ECU Assembly - -
    Tip:

    The standard normal voltage between each pair of hybrid vehicle control ECU assembly terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the hybrid vehicle control ECU assembly terminal locations.

    Table 1. Hybrid Vehicle Control ECU Assembly
    Terminal No. (Symbol) Wiring Color Input/Output Terminal Description Condition Specified Condition
    A77-28 (HMCH) - G92-6 (E1) G - W-B IN/OUT CAN Communication signal Power switch on (IG)

    Pulse generation

    (Waveform 1)

    A77-1 (MREL) - G92-6 (E1)

    G*1 - W-B

    LG*2 - W-B

    OUT Main relay Power switch on (IG) 11 to 14 V
    A76-12 (LIN3) - G92-6 (E1) V - W-B IN/OUT LIN communication signal Power switch on (READY) Pulse generation
    A77-20 (HMCL) - G92-6 (E1) R - W-B IN/OUT CAN Communication signal Power switch on (IG)

    Pulse generation

    (Waveform 1)

    *1: for LHD

    *2: for RHD


    1. Oscilloscope waveforms

      Tip:

      Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


      1. B004SPVE06

        Waveform 1 (CAN communication signal)

        Item Content
        Terminal

        CH1: A77-28 (HMCH) - G92-6 (E1)

        CH2: A77-20 (HMCL) - G92-6 (E1)

        Equipment Setting 1 V/DIV., 50 μs./DIV.
        Condition Power switch on (IG)
        Tip:

        The waveform will vary depending on the content of the digital communication (digital signal).