ULTRASONIC SENSOR(for Rear) INSPECTION

PROCEDURE


  1. INSPECT REAR CORNER ULTRASONIC SENSOR (for LH Side)


    1. B004YO2C22
      *a Component without harness connected (Rear Corner Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O1-4 (BI) - O1-6 (EI) Always 10 kΩ or higher
      O1-4 (BI) - O1 -1 (BO) Always Below 1 Ω
      O1-5 (SI) - O1 -2 (SO) Always Below 30 Ω
      O1-6 (EI) - O1 -3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the rear corner ultrasonic sensor.

  2. INSPECT REAR CORNER ULTRASONIC SENSOR (for RH Side)


    1. B004YO2C24
      *a Component without harness connected (Rear Corner Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O4-4 (BI) - O4-6 (EI) Always 10 kΩ or higher
      O4-4 (BI) - O4-1 (BO) Always Below 1 Ω
      O4-5 (SI) - O4-2 (SO) Always Below 30 Ω
      O4-6 (EI) - O4-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the rear corner ultrasonic sensor.

  3. INSPECT REAR CENTER ULTRASONIC SENSOR (for LH Side)


    1. B004YO2C25
      *a Component without harness connected (Rear Center Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O2-4 (BI) - O2-6 (EI) Always 10 kΩ or higher
      O2-4 (BI) - O2-1 (BO) Always Below 1 Ω
      O2-5 (SI) - O2-2 (SO) Always Below 30 Ω
      O2-6 (EI) - O2-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the rear center ultrasonic sensor.

  4. INSPECT REAR CENTER ULTRASONIC SENSOR (for RH Side)


    1. B004YO2C26
      *a Component without harness connected (Rear Center Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O3-4 (BI) - O3-6 (EI) Always 10 kΩ or higher
      O3-4 (BI) - O3-1 (BO) Always Below 1 Ω
      O3-5 (SI) - O3-2 (SO) Always Below 30 Ω
      O3-6 (EI) - O3-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the rear center ultrasonic sensor.