Click here

ULTRASONIC SENSOR(for Front) INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT FRONT CORNER ULTRASONIC SENSOR (for LH Side)


    1. B004YO2C18
      *a Component without harness connected (Front Corner Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C1-4 (BI) - C1-6 (EI) Always 10 kΩ or higher
      C1-4 (BI) - C1 -1( BO) Always Below 1 Ω
      C1-5 (SI) - C1 -2 (SO) Always Below 30 Ω
      C1-6 (EI) - C1 -3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front corner ultrasonic sensor.

  2. Click here

    INSPECT FRONT CORNER ULTRASONIC SENSOR (for RH Side)


    1. B004YO2C19
      *a Component without harness connected (Front Corner Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C4-4 (BI) - C4-6 (EI) Always 10 kΩ or higher
      C4-4 (BI) - C4-1 (BO) Always Below 1 Ω
      C4-5 (SI) - C4-2 (SO) Always Below 30 Ω
      C4-6 (EI) - C4-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front corner ultrasonic sensor.

  3. Click here

    INSPECT FRONT CENTER ULTRASONIC SENSOR (for LH Side)


    1. B004YO2C20
      *a Component without harness connected (Front Center Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C2-4 (BI) - C2-6 (EI) Always 10 kΩ or higher
      C2-4 (BI) - C2-1 (BO) Always Below 1 Ω
      C2-5 (SI) - C2-2 (SO) Always Below 30 Ω
      C2-6 (EI) - C2-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front center ultrasonic sensor.

  4. Click here

    INSPECT FRONT CENTER ULTRASONIC SENSOR (for RH Side)


    1. B004YO2C21
      *a Component without harness connected (Front Center Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C3-4 (BI) - C3-6 (EI) Always 10 kΩ or higher
      C3-4 (BI) - C3-1 (BO) Always Below 1 Ω
      C3-5 (SI) - C3-2 (SO) Always Below 30 Ω
      C3-6 (EI) - C3-3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front center ultrasonic sensor.