POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM DATA LIST / ACTIVE TEST


  1. READ DATA LIST

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Turn the power switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus: Body Electrical / Tilt & Telescopic / Data List.

    6. According to the display on the GTS, read the Data List.


      Body Electrical > Tilt&Telescopic > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Total Distance Traveled Driving distance

      Min.: 0

      Max.: 999999

      - -
      Total Distance Traveled - Unit Driving distance unit km or mile - -
      Tilt Up Limit Uppermost tilt position Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Tilt Down Limit Lowermost tilt position Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Telescopic Short Limit Shortest telescopic position Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Telescopic Long Limit Longest telescopic position Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Tilt&Telescopic Memory 1 Tilt and telescopic memory position 1 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Tilt&Telescopic Memory 2 Tilt and telescopic memory position 2 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Tilt&Telescopic Memory 3 Tilt and telescopic memory position 3 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Driver Information Memory 1 Driver Information Memory 1 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Driver Information Memory 2 Driver Information Memory 2 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Driver Information Memory 3 Driver Information Memory 3 Not Mem or Mem

      Not Mem: Position not memorized

      Mem: Position memorized

      -
      Ignition Switch (CAN) Communication state of power switch ON or OFF

      ON: Communication normal

      OFF: Communication interrupted

      -
      Handle Position Steering wheel position signal Away or Return

      Away: Steering wheel in away position

      Return: Steering wheel in return position

      -
      Ignition Switch Input state of power switch ON or OFF

      ON: Input signal normal

      OFF: Input signal interrupted

      -
      Tilt Manual Switch Up Input state of tilt up switch ON or OFF - -
      Tilt Manual Switch Down Input state of tilt down switch ON or OFF - -
      Telescopic Manual Switch Short Input state of telescopic contract switch ON or OFF - -
      Telescopic Manual Switch Long Input state of telescopic extend switch ON or OFF - -
      Tilt&Telescopic Manual Switch Voltage Voltage data of tilt and telescopic switch

      Min.: 0.00 V

      Max.: 4.99 V

      Neutral position: Below 0.20 V

      Tilt up: 1.67 to 2.13 V

      Tilt down: 0.54 to 0.74 V

      Telescopic contract: 1.08 to 1.40 V

      Telescopic extend: 2.22 to 2.77 V

      -
      ECU Power Source Voltage Voltage data of power supply

      Min.: 0.00 V

      Max.: 19.99 V

      11.00 to 14.00 V -
      Tilt Position Current tilt position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Position Current telescopic position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Return Memory Position Memorized tilt return position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Return Memory Position Memorized telescopic return position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Up Limit Position Uppermost tilt position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Down Limit Position Lowermost tilt position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Short Limit Position Shortest telescopic position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Long Limit Position Longest telescopic position data

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Memory Position 1 Tilt data of memory position 1

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Memory Position 1 Telescopic data of memory position 1

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Memory Position 2 Tilt data of memory position 2

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Memory Position 2 Telescopic data of memory position 2

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Memory Position 3 Tilt data of memory position 3

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Telescopic Memory Position 3 Telescopic data of memory position 3

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Vehicle Speed Vehicle speed data

      Min.: 0 km/h (0 mph)

      Max.: 255 km/h (158 mph)

      Vehicle stopped: 0 km/h (0 mph)

      When driving at constant speed: No large fluctuations

      -
      Driver Tilt Memory Position 1 Driver tilt memory position 1

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Driver Telescopic Memory Position 1 Driver telescopic memory position 1

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Driver Tilt Memory Position 2 Driver tilt memory position 2

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Driver Telescopic Memory Position 2 Driver telescopic memory position 2

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Driver Tilt Memory Position 3 Driver tilt memory position 3

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Driver Telescopic Memory Position 3 Driver telescopic memory position 3

      Min.: 0

      Max.: 65535

      28627 to 36864 -
      Tilt Motor Machine Lock Memory Data Tilt Motor Machine Lock Memory Data Data or Not Data - -
      Telescopic Motor Machine Lock Memory Data Telescopic Motor Machine Lock Memory Data Data or Not Data - -
      Autoaway/Return Operation Setting Autoaway/Return Operation Setting Tilt ON, Telescopic ON, Tilt&Telescopic ON or Tilt&Telescopic OFF

      Tilt ON: Only tilt operations permitted

      Telescopic ON: Only telescopic operations permitted

      Tilt&Telescopic ON: Tilt and telescopic operations permitted

      Tilt&Telescopic OFF: Tilt and telescopic operations prohibited

      -
  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Turn the power switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus: Body Electrical / Tilt & Telescopic / Active Test.

    6. According to the display on the GTS, perform the Active Test.


      Body Electrical > Tilt&Telescopic > Active Test
      Tester Display Measurement Item Control Range
      Tilt Motor Tilt operation UP/DOWN
      Telescopic Motor Telescopic operation LONG/SHORT