CHECK ECM
Tech Tips
The standard voltage, resistance and waveform between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals is also indicated. The result of checks should be compared with the standard voltage, resistance and waveform for each pair of the terminals as displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A56-32 (FUEL) - D1-53 (E1) | B - W-B | Trunk and fuel switch assembly (fuel lid opener switch) signal | Trunk and fuel switch assembly (fuel lid opener switch) pressed | Below 1 V |
| Trunk and fuel switch assembly (fuel lid opener switch) not pressed | 11 to 14 V | |||
| A56-37 (LIDO) - D1-53 (E1) | B - W-B | Fuel lid with motor lock assembly (fuel lid courtesy switch) signal | Fuel lid closed | Below 1 V |
| Fuel lid open | 11 to 14 V | |||
| A56-59 (LSTM) - D1-53 (E1) | GR - W-B | Fuel lid operation signal for combination meter assembly | Multi-information display displaying "Please Wait Now Opening" | Pulse generation (see waveform 1) |
| Multi-information display displaying "Close Fuel Lid" | Pulse generation (see waveform 2) |
|||
| Multi-information display displaying "Refuel Ready" | Pulse generation (see waveform 3) |
|||
| Power switch on (IG) | 11 to 14 V | |||
| D1-32 (FREL) - D1-53 (E1) | B - W-B | Fuel lid with motor lock assembly operation signal | Fuel lid with motor lock assembly operating | Below 1 V |
| Fuel lid with motor lock assembly not operating | 11 to 14 V |
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | A56-59 (LSTM) - D1-53 (E1) |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Please Wait Now Opening" |
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | A56-59 (LSTM) - D1-53 (E1) |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Close Fuel Lid" |
Using an oscilloscope, check waveform 3.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | A56-59 (LSTM) - D1-53 (E1) |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Refuel Ready" |
CHECK COMBINATION METER ASSEMBLY
Disconnect the G34 and G35 combination meter assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G34-21 (IG+) - Body ground | LA-G - Body ground | Power switch signal | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| G34-22 (B) - Body ground | LA-B - Body ground | Auxiliary battery | Power switch off | 11 to 14 V |
| G35-1 (B) - Body ground | LA-P - Body ground | Auxiliary battery | Power switch off | 11 to 14 V |
| G34-40 (EP) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
Reconnect the G34 and G35 combination meter assembly connectors.
Measure the waveform and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G34-11 (LST1) - Body ground | GR - Body ground | Fuel lid operation signal for combination meter assembly | Multi-information display displaying "Please Wait Now Opening" | Pulse generation (see waveform 1) |
| Multi-information display displaying "Close Fuel Lid" | Pulse generation (see waveform 2) |
|||
| Multi-information display displaying "Refuel Ready" | Pulse generation (see waveform 3) |
|||
| Power switch on (IG) | 11 to 14 V |
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G34-11 (LST1) - Body ground |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Please Wait Now Opening" |
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G34-11 (LST1) - Body ground |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Close Fuel Lid" |
Using an oscilloscope, check waveform 3.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G34-11 (LST1) - Body ground |
| Tool Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Multi-information display displaying "Refuel Ready" |