WINDOW DEFOGGER SYSTEM DATA LIST / ACTIVE TEST


  1. READ DATA LIST

    Tech Tips

    Using the GTS to read the Data List allows values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Power Integration No.3 / Data List.

    5. According to the display on the GTS, read the Data List.


      Body Electrical > Power Integration No.3 > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Rear Defogger Input Signal Window defogger switch signal input condition ON or OFF

      ON: Window defogger switch is on

      OFF: Window defogger switch is off

      -
      Rear Defogger Output Signal Window defogger output condition ON or OFF

      ON: Window defogger operates

      OFF: Window defogger does not operate

      -
      Rear Defogger Output Current Window defogger current Min.: 0, Max.: 255 A Approximately 20 A (Max. 22 A) Window defogger current when output is on
      Status of Rear Defogger Fuse Window defogger fuse condition Disconnect or Connect

      Disconnect: Fuse shut off

      Connect: Fuse not shut off

      -
      Rear Defogger Fuse Shut Off History Window defogger fuse shut off history ON or OFF

      ON: Fuse has shut off history

      OFF: Fuse has no shut off history

      -
  2. Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    ACTIVE TEST


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. According to the display on the GTS, perform the Active Test.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Defogger Relay (Rear) Back window glass (window defogger wire) OFF or ON -