DESCRIPTION
If the manual up and down function operates normally but the auto up and down function does not, then fail-safe mode may be functioning.
If power window initialization has not been performed, the auto up and down function will not operate.
WIRING DIAGRAM
for LHD:
| *1 | Multiplex Network Master Switch Assembly |
| *2 | Front Multiplex Network Door ECU LH |
| *3 | Front Power Window Regulator Motor Assembly LH |
| *4 | LIN Communication Line |
for RHD:
| *1 | Multiplex Network Master Switch Assembly |
| *2 | Front Multiplex Network Door ECU RH |
| *3 | Front Power Window Regulator Motor Assembly RH |
| *4 | LIN Communication Line |
CAUTION / NOTICE / HINT
Note
The power window control system uses the LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting. Troubleshoot the power window control system after confirming that the communication system is functioning properly.
If the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) has been replaced with a new one, initialize the power window control system.
Check that the "D Window Auto Up" and "D Window Auto Down" power window control system customize settings are "ON" before proceeding with work.
After the catch protection function operates, the auto operation is not performed the first time auto up is performed. All auto up operations performed after the first operate normally.
Tech Tips
If the pulse sensor built into the front power window regulator motor assembly LH is malfunctioning, the power window control system enters fail-safe mode. The remote up and down and auto up and down functions cannot be operated during fail-safe mode. However, the power window can be closed by holding the multiplex network master switch assembly at the auto up position, and opened manually by pushing down the multiplex network master switch assembly.
PROCEDURE
READ VALUE USING GTS (MASTER SWITCH)
Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| D Door P/W Auto SW | Driver door power window auto switch signal | OFF or ON | OFF: Driver door power window auto switch not being operated ON: Driver door power window auto switch being operated |
- |
| Tester Display |
|---|
| D Door P/W Auto SW |
| OK |
|---|
| On the GTS screen, ON or OFF is displayed accordingly. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY Click here |
| OK |
|
READ VALUE USING GTS (D-DOOR MOTOR)
Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| D Door P/W Auto SW | Driver door power window auto switch signal | OFF or ON | OFF: Driver door power window auto switch not being operated ON: Driver door power window auto switch being operated |
- |
| Tester Display |
|---|
| D Door P/W Auto SW |
| OK |
|---|
| On the GTS screen, ON or OFF is displayed accordingly. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
PERFORM INITIALIZATION Click here |
| C |
|
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY Click here |
| A |
|
PERFORM INITIALIZATION
Initialize the front power window regulator motor assembly LH.
| OK |
|---|
| Power window system operates normally. |
| Result | |||
|---|---|---|---|
|
| OK |
|
END (PROBLEM DUE TO INITIALIZATION FAILURE) |
| NG |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH Click here |
PERFORM INITIALIZATION
Initialize the front power window regulator motor assembly RH.
| OK |
|---|
| Power window system operates normally. |
| Result | |||
|---|---|---|---|
|
| OK |
|
END (PROBLEM DUE TO INITIALIZATION FAILURE) |
| NG |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH Click here |
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
Temporarily replace the multiplex network master switch assembly with a new or normally functioning one.
| OK |
|---|
| Power window system operates normally. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE) |
| B |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH Click here |
| C |
|
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH Click here |