Click here

ROOM TEMPERATURE SENSOR(for Rear Side) INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT NO. 2 COOLER THERMISTOR


    1. B004UVXC03
      *a

      Component without harness connected

      (Cooler thermistor (No. 2 room temperature))

      *b Resistance (kΩ)
      *c Temperature (°C (°F))
      *d Allowable Range

      RH Side:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        J2-1 - J2-2 10°C 3.00 to 3.73 kΩ
        15°C 2.45 to 2.88 kΩ
        20°C 1.95 to 2.30 kΩ
        25°C 1.60 to 1.80 kΩ
        30°C 1.28 to 1.47 kΩ
        35°C 1.00 to 1.22 kΩ
        40°C 0.80 to 1.00 kΩ
        45°C 0.65 to 0.85 kΩ
        50°C 0.50 to 0.70 kΩ
        55°C 0.44 to 0.60 kΩ
        60°C 0.36 to 0.50 kΩ
        Tip:
        • If the temperature sensor is touched, body heat will affect the sensor and a correct judgment cannot be made. Therefore, when inspecting the sensor, hold it by the connector.

        • When measuring, the sensor temperature must be the same as the ambient temperature.

    2. B004UVXC04
      *a

      Component without harness connected

      (Cooler thermistor (No. 2 room temperature))

      *b Resistance (kΩ)
      *c Temperature (°C (°F))
      *d Allowable Range

      LH Side:


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        J6-1 - J6-2 10°C 3.00 to 3.73 kΩ
        15°C 2.45 to 2.88 kΩ
        20°C 1.95 to 2.30 kΩ
        25°C 1.60 to 1.80 kΩ
        30°C 1.28 to 1.47 kΩ
        35°C 1.00 to 1.22 kΩ
        40°C 0.80 to 1.00 kΩ
        45°C 0.65 to 0.85 kΩ
        50°C 0.50 to 0.70 kΩ
        55°C 0.44 to 0.60 kΩ
        60°C 0.36 to 0.50 kΩ
        Tip:
        • If the temperature sensor is touched, body heat will affect the sensor and a correct judgment cannot be made. Therefore, when inspecting the sensor, hold it by the connector.

        • When measuring, the sensor temperature must be the same as the ambient temperature.