Click here

CONDENSER REASSEMBLY

Click here
Click here

PROCEDURE


  1. Click here

    INSTALL COOLER DRYER


    1. B004W3GC01
      *a Modulator

      Using needle-nose pliers, install a new cooler dryer to the modulator.

    2. B004UA1

      Sufficiently apply compressor oil to the 3 new O-rings and the fitting surface of a new cap.

      Compressor Oil
      ND-OIL 11 or equivalent
      Note:
      • Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in leakage of electric power.

      • Keep the O-ring and O-ring fitting surface free of foreign matter.

    3. B004RCFC01
      *a Modulator

      Using a 14 mm straight hexagon socket wrench, install the cap to the modulator.

      4.0 N*m 41 kgf*cm 35 in.*lbf
      Note:

      Make sure not to cut the O-ring while installing it. (Cut O-rings cannot be installed)