DESCRIPTION
If fresh/recirculation mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor |
|---|---|
|
|
PROCEDURE
CHECK FOR DTC (AIR CONDITIONING SYSTEM: B1423, B14B8)
Clear the DTC.
Check for DTCs.
| OK |
|---|
| DTC B1423 and B14B8 are not output. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
GO TO DTC B1423 Click here |
| C |
|
GO TO DTC B14B8 Click here |
| A |
|
CHECK CUSTOMIZE SETTING
Use the following customize setting methods to confirm that the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
Check setting using Techstream
Check setting by multi-display
| OK |
|---|
| Customize setting is "OFF". |
| Result | |||
|---|---|---|---|
|
| NG |
|
CHANGE CUSTOMIZE SETTING IS ON |
| OK |
|
READ VALUE USING GTS (EMISSION GAS SENSOR)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Emission Gas Sensor | Emission gas (HC, CO) | Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | Smog ventilation sensor malfunction |
| Tester Display |
|---|
| Emission Gas Sensor |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
INSPECT SMOG VENTILATION SENSOR
Remove the smog ventilation sensor.
Inspect the smog ventilation sensor.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE SMOG VENTILATION SENSOR Click here |
| OK |
|
READ VALUE USING GTS (AMBIENT TEMP SENSOR)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly system malfunction
|
| Tester Display |
|---|
| Ambient Temp Sensor |
| OK |
|---|
| The value of the display does not change frequently. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO AMBIENT TEMPERATURE DISPLAY SYSTEM Click here |
| OK |
|
READ VALUE USING GTS (COOLANT TEMPERATURE)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. Tech Tips
|
| Tester Display |
|---|
| Coolant Temperature |
| OK |
|---|
| The value of the display does not change frequently. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING SYSTEM Click here |
| OK |
|
CHECK REFRIGERANT PRESSURE
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG Max.: 3294.3 kPaG |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
for HFC-134a (R134a): Click here
for HFO-1234yf (R1234yf): Click here
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Standard Pressure |
|---|
| Low pressure side |
| 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) |
| High pressure side |
| 1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi) |
Compare the values displayed in the Data List and on the manifold gauge.
| OK |
|---|
| The values displayed in the Data List and on the manifold gauge match. |
| Result | |||
|---|---|---|---|
|
| OK |
|
GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE) Click here |
| NG |
|
REPLACE AIR CONDITIONER PRESSURE SENSOR Click here |