| DTC Code | DTC Name |
|---|---|
| B1423 | Pressure Sensor Circuit |
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Pressure Sensor Circuit |
|
|
- |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
PROCEDURE
CHECK FOR DTC
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
GO TO DTC B14B8Click here
CHECK REFRIGERANT SHORTAGE
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature*1 | 0 to 49°C (32 to 120°F) |
| Air conditioning inlet temperature*2 | 25 to 49°C (77 to 120°F) |
| Setting temperature | MAX COLD |
| Blower damper position | Recirculation |
| Outlet damper position | FACE |
| Blower speed | HI |
*1: If the ambient temperature is not within the range shown, do not perform this check.
*2: The air inlet temperature can be judged correctly only if it is within an appropriate range of 25 to 79°C (77 to 174°F). Therefore, use the heater mode to adjust the temperature so that it falls within the appropriate range and then perform the check.
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
REPAIR AIR CONDITIONING SYSTEM LEAK
Identify the area where refrigerant leaks from.
for HFC-134a (R134a):Click here
for HFO-1234yf (R1234yf):Click here
Repair the identified area of the air conditioning system.
Evacuate the air conditioning system.
| Result | ||
|---|---|---|
|
CHARGE SYSTEM WITH REFRIGERANT
for HFC-134a (R134a):Click here
for HFO-1234yf (R1234yf):Click here
CHECK REFRIGERANT PRESSURE
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG Max.: 3294.3 kPaG |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
for HFC-134a (R134a):Click here
for HFO-1234yf (R1234yf):Click here
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Standard Pressure |
|---|
| Low pressure side |
| 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) |
| High pressure side |
| 1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi) |
Compare the values displayed in the Data List and on the manifold gauge.
| OK |
|---|
| The values displayed in the Data List and on the manifold gauge match. |
| Result | |||
|---|---|---|---|
|
CHECK REFRIGERANT PRESSURE
for HFC-134a (R134a):Click here
for HFO-1234yf (R1234yf):Click here
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
Disconnect the air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
Disconnect the air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
Disconnect the G64 air conditioning amplifier assembly connector.
Disconnect the A39 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT)
Measure the voltage when the following conditions are met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG Max.: 3294.3 kPaG |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
| OK |
|---|
| The voltage and value displayed in the Data List change. |
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPLACE AIR CONDITIONER PRESSURE SENSORClick here
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
Disconnect the G63 air conditioning amplifier assembly connector.
Disconnect the A39 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
Disconnect the G64 air conditioning amplifier assembly connector.
Disconnect the A39 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR