| DTC Code | DTC Name |
|---|---|
| B1413 | Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1413 | Evaporator Temperature Sensor Circuit |
|
|
Memorized |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS (EVAPORATOR FIN THERMISTOR)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor system malfunction
|
| Tester Display |
|---|
| Evaporator Fin Thermistor |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | |||
|---|---|---|---|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
INSPECT NO. 1 COOLER THERMISTOR
Remove the No. 1 cooler thermistor.
Inspect the No. 1 cooler thermistor.
| Result | |||
|---|---|---|---|
|
REPLACE NO. 1 COOLER THERMISTORClick here
CHECK AIR CONDITIONING HARNESS ASSEMBLY
| *1 | Air Conditioning Harness Assembly | - | - |
Remove the air conditioning harness assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPLACE AIR CONDITIONING HARNESS ASSEMBLYClick here