CAUTION / NOTICE / HINT
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
w/ Canister Pump Module:
w/o Canister Pump Module:
PROCEDURE
INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
w/ Canister Pump Module:
w/o Canister Pump Module:
Install the mass air flow meter sub-assembly with the 2 screws.
If the mass air flow meter sub-assembly has been struck or dropped, replace it.
If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
Make sure that the O-ring is not cracked or does not move out of place during installation.
Connect the mass air flow meter sub-assembly connector.
INSTALL LOWER RADIATOR AIR DEFLECTOR
INSTALL UPPER RADIATOR SUPPORT SEAL
INSTALL RADIATOR COVER PLATE