PROCEDURE
INSPECT HEIGHT CONTROL COMPRESSOR THERMISTOR ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| *1 | Sensing Portion | - | - |
| *a | Component without harness connected (Height Control Compressor Thermistor Assembly) |
*b | Resistance (kΩ) |
| *c | Temperature (°C (°F)) | - | - |
| Standard Resistance | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
When measuring, the sensor temperature. must be the same as the ambient temperature.
If the result is not as specified, replace the height control compressor thermistor assembly.