CAUTION / NOTICE / HINT
Be sure to read the "PRECAUTION" thoroughly before servicing.
In order to prevent the battery from becoming fully depleted, connect the battery charger to the auxiliary battery when turning the power switch on (IG) to charge the battery.
Keep the power supply connected to prevent the GTS battery from becoming fully depleted.
PROCEDURE
AIR SUSPENSION CONTROL PROHIBITED
REMOVE W/O RELAY COMPRESSOR & DRYER ASSEMBLY
REMOVE HEIGHT CONTROL COMPRESSOR THERMISTOR ASSEMBLY
Disconnect the connector.
Detach the clamp and remove the height control compressor thermistor assembly.