CHECK SUSPENSION CONTROL ECU
Measure the voltage and resistance according to the value(s) in the table below.
Inspect the connectors from the back side while the connectors are connected.
| Terminal NO. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L104-1 (SLRR) - L105-3 (GND) | P - W-B | NO. 2 height control valve sub-assembly RH | During NO. 2 height control valve sub-assembly RH operation | 8 V or higher |
| NO. 2 height control valve sub-assembly RH not operating | Below 1 V | |||
| L104-2 (SLRL) - L105-3 (GND) | B - W-B | NO. 2 height control valve sub-assembly LH | During NO. 2 height control valve sub-assembly LH operation | 8 V or higher |
| NO. 2 height control valve sub-assembly LH not operating | Below 1 V | |||
| L104-3 (SLEX) - L105-3 (GND) | L - W-B | Exhaust valve (NO. 1 height control compressor) | During exhaust valve (NO. 1 height control compressor) operation | 8 V or higher |
| Exhaust valve (NO. 1 height control compressor) not operating | Below 1 V | |||
| L104-7 (SPS2) - L105-3 (GND) | R - W-B | Height control way | Power switch on (IG) | 0.5 to 4.5 V |
| L104-8 (SPG2) - L105-3 (GND) | L - W-B | Height control way ground | Always | Below 1 Ω |
| L104-9 (SPB2) - L105-3 (GND) | P - W-B | Height control way power source | Power switch on (IG) | 4.75 to 5.25 V |
| L104-10 (RC) - L105-3 (GND) | B - W-B | Suspension control relay (AIRSUS) | During NO. 1 height control compressor operation | 11 to 14 V |
| NO. 1 height control compressor not operating | Below 1 V | |||
| L104-11 (SLC1) - L105-3 (GND) | SB - W-B | NO. 3 height control valve (NO. 1 height control compressor) | During NO. 3 height control valve (NO. 1 height control compressor) operation | Below 1 V |
| NO. 3 height control valve (NO. 1 height control compressor) not operating | 8 V or higher | |||
| L104-12 (SLC2) - L105-3 (GND) | G - W-B | NO. 3 height control valve (NO. 1 height control compressor) | During NO. 3 height control valve (NO. 1 height control compressor) operation | Below 1 V |
| NO. 3 height control valve (NO. 1 height control compressor) not operating | 8 V or higher | |||
| L104-13 (SLC4) - L105-3 (GND) | LG - W-B | NO. 3 height control valve (NO. 1 height control compressor) | During NO. 3 height control valve (NO. 1 height control compressor) operation | Below 1 V |
| NO. 3 height control valve (NO. 1 height control compressor) not operating | 8 V or higher | |||
| L104-14 (SLC3) - L105-3 (GND) | V - W-B | NO. 3 height control valve (NO. 1 height control compressor) | During NO. 3 height control valve (NO. 1 height control compressor) operation | Below 1 V |
| NO. 3 height control valve (NO. 1 height control compressor) not operating | 8 V or higher | |||
| L104-16 (RM-) - L105-3 (GND) | LG - W-B | Motor lock (-) | Always | Below 1 Ω |
| L104-18 (RM+) - L105-3 (GND) | Y - W-B | Motor lock (+) | During NO. 1 height control compressor operation | Below 1 V |
| NO. 1 height control compressor not operating | 8 V or higher | |||
| L104-19 (SPB) - L105-3 (GND) | P - W-B | Height control pressure sensor power source | Power switch on (IG) | 4.75 to 5.25 V |
| L104-20 (SPG) - L105-3 (GND) | L - W-B | Height control pressure sensor ground | Always | Below 1 Ω |
| L104-21 (PACC) - L105-3 (GND) | R - W-B | Height control pressure sensor | Power switch on (IG) | 0.5 to 4.5 V |
| L104-22 (SHG3) - L105-3 (GND) | V - W-B | Rear height control sensor sub-assembly RH ground | Always | Below 1 Ω |
| L104-23 (SHRR) - L105-3 (GND) | P - W-B | Rear height control sensor sub-assembly RH | Power switch on (IG) | 0.5 to 4.5 V |
| L104-24 (SHB3) - L105-3 (GND) | B - W-B | Rear height control sensor sub-assembly RH power source | Power switch on (IG) | 4.75 to 5.25 V |
| L104-25 (SHG4) - L105-3 (GND) | GR - W-B | Rear height control sensor sub-assembly LH ground | Always | Below 1 Ω |
| L104-26 (SHRL) - L105-3 (GND) | LG - W-B | Rear height control sensor sub-assembly LH | Power switch on (IG) | 0.5 to 4.5 V |
| L104-27 (SHB4) - L105-3 (GND) | R - W-B | Rear height control sensor sub-assembly LH power source | Power switch on (IG) | 4.75 to 5.25 V |
| Terminal NO. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L105-1 (BAT) - L105-3 (GND) | B - W-B | Power source | Always | 11 to 14 V |
| L105-3 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| L105-8 (IG) - L105-3 (GND) | L - W-B | IG power source | Power switch on (IG) | 11 to 14 V |
| L105-9 (CANL) - L105-10 (CANH) | W - G | CAN communication line | Power switch off | 54 to 69 Ω |
| L105-11 (SHB2) - L105-3 (GND) | B - W-B | Front height control sensor sub-assembly LH power source | Power switch on (IG) | 4.75 to 5.25 V |
| L105-12 (SHG1) - L105-3 (GND) | R - W-B | Front height control sensor sub-assembly RH ground | Always | Below 1 Ω |
| L105-13 (SHFR) - L105-3 (GND) | P - W-B | Front height control sensor sub-assembly RH | Power switch on (IG) | 0.5 to 4.5 V |
| L105-14 (SLFR) - L105-3 (GND) | Y - W-B | NO. 1 height control valve sub-assembly RH | During NO. 1 height control valve sub-assembly RH operation | Below 1 V |
| NO. 1 height control valve sub-assembly RH not operating | 8 V or higher | |||
| L105-16 (SLFL) - L105-3 (GND) | G - W-B | NO. 1 height control valve sub-assembly LH | During NO. 1 height control valve sub-assembly LH operation | Below 1 V |
| NO. 1 height control valve sub-assembly RH not operating | 8 V or higher | |||
| L105-18 (UPSW) - L105-3 (GND) | SB - W-B | Height control switch (integration control and panel assembly) | Power switch on (READY), height control switch (integration control and panel assembly) off | 11 to 14 V |
| Power switch on (READY), height control switch (integration control and panel assembly) held on | Below 1.5 V | |||
| L105-21 (CA2L) - L105-22 (CA2H) | W - V | CAN communication line | Power switch off | 54 to 69 Ω |
| L105-23 (SHFL) - L105-3 (GND) | L - W-B | Front height control sensor sub-assembly LH | Power switch on (IG) | 0.5 to 4.5 V |
| L105-24 (SHG2) - L105-3 (GND) | GR - W-B | Front height control sensor sub-assembly LH ground | Always | Below 1 Ω |
| L105-25 (SHB1) - L105-3 (GND) | V - W-B | Front height control sensor sub-assembly RH power source | Power switch on (IG) | 4.75 to 5.25 V |
| L105-26 (STG) - L105-3 (GND) | Y - W-B | Height control compressor thermistor assembly | Always | Below 1 Ω |
| L105-28 (TOIL) - L105-3 (GND) | LG - W-B | Height control compressor thermistor assembly | Power switch on (IG) | 0.2 to 4.6 V |