RELAY INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT OIL PUMP RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the OIL PUMP relay.

  2. Click here

    INSPECT P CON MTR RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the P CON MTR relay.

  3. Click here

    INSPECT P CON MTR 2 RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the P CON MTR 2 relay.