RELAY INSPECTION

PROCEDURE


  1. INSPECT OIL PUMP RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the OIL PUMP relay.

  2. INSPECT P CON MTR RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the P CON MTR relay.

  3. INSPECT P CON MTR 2 RELAY


    1. B004R3VN13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminal 1 and 2 10 MΩ or higher
      3 - 5 Battery voltage is applied to terminal 1 and 2 Below 1 Ω

      If the result is not as specified, replace the P CON MTR 2 relay.